Velleman-projects K8006 Assembly instructions Bedienungsanleitung Seite 10

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 16
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 9
10
Choose a suitable location for the unit. Probably, the best location is near the
fuse box. An optional enclosure (B8006) is available, for safe installation of the
unit on a DIN rail. Whatever enclosure you use, make sure to provide sufficient
airflow, as the dimmer modules might run hot during use. If you choose the
optional B8006 enclosure, drill a number of ventilation holes in the top and
bottom part of the cover lid.
The drawing below shows a connection example.
Make sure your wiring complies with the local safety requirements.
If doubt, consult a licensed technician !
15. Final Connection
24VAC LOAD1N
1C2C3CC
VELLEMAN K8006
L
SUPPLY
C
LOAD2NLOAD3NLOAD4NLOAD5NN
12345
DAN GER
HIGH
VOLTAGE
24VAC
PRIM
L N
LN
PUSH BUTTONS
AC POWER
CIRCUIT
BREAKER
16A
TRANSFORMER
OPEN
COLLECTOR
INPUTS
4C5
SW1 SW2 SW3 SW4 SW5
2K21N4148
C
LED
C
A
C
PUSH BUTTON
Final Connection
REMARK: 10 LEDs are provided,
together with diodes and resistors, to
allow push button illumination.
Do not use more than 5 illuminated
push buttons per channel.
Fig. 1.0
Seitenansicht 9
1 2 ... 5 6 7 8 9 10 11 12 13 14 15 16

Kommentare zu diesen Handbüchern

Keine Kommentare